Fixture Type Transformers » Bulletin F-4.1
General Description:
• Fixture Type Transformer
• Inline Single Lugs RWMA
• Frame Cross Section 7-3/4" X 10-1/4"
Ordering Instructions:
• Order by model number shown
• Add "X" to model number if transformer is to be fully potted
• Specify primary conduit opening desired 1-1/4NPT or 1-1/2
• Specify tap switch position on 5-way mount models

• To request a Drawing, click on the Drawing No. below, and complete the request form.

Wound Core

KVA Rating 110C Rise Secondary Voltage Range Tap Switch Location Primary Connection Model Number Weight Approx. Drawing No. Frame Letter Turns Ratio (xx:1 Unless in Series then xx:2) 440 Volt
220V/60 Hz 440V/60 Hz Tap 1 Tap 2 Tap 3 Tap 4 Tap 5
120 6.8 to 9.1 Volts
4 Steps
End Mount Disconnect Plug
Solderless Lug
F226120C1BEWX

F446120C1AEWX
F446120C1BEWX

240 R1384 C 64 60 56 52 48
5 Way
Mount
Disconnect Plug
Solderless Lug
F226120C1DEWX F446120C1CEWX
F446120C1DEWX
247 R1385
150 9.2 to 11.6 Volts
4 Steps
End Mount Disconnect Plug
Solderless Lug
F226150D1BEWX F446150D1AEWX
F446150D1BEWX
265 R1384 D 48 44 41 38 NA
5 Way
Mount
Disconnect Plug
Solderless Lug
F226150D1DEWX F446150D1CEWX
F446150D1DEWX
272 R1385
150 9.2 to 12.2 Volts
4 Steps
End Mount Disconnect Plug
Solderless Lug
F226150F1BEWX F446150F1AEWX
F446150F1BEWX
280 R1384 F 48 44 40 36 NA
5 Way
Mount
Disconnect Plug
Solderless Lug
F226150F1DEWX F446150F1CEWX
F446150F1DEWX
287 R1385
200 12.5 to 15.2 Volts
4 Steps
End Mount Disconnect Plug
Solderless Lug
-- F446200DL1AEWX
F446200DL1BEWX
300 R1384 DL 35 33 31 29 NA
5 Way
Mount
Disconnect Plug
Solderless Lug
-- F446200DL1CEWX
F446200DL1DEWX
307 R1385

Stacked Core

KVA Rating 110C Rise Secondary Voltage Range Tap Switch Location Primary Connection Model Number Weight Approx. Drawing No. Frame Letter Turns Ratio (xx:1 Unless in Series then xx:2) 440 Volt
220V/60 Hz 440V/60 Hz Tap 1 Tap 2 Tap 3 Tap 4 Tap 5
80 5.0 to 7.5 Volts
4 Steps
End Mount Disconnect Plug
Solderless Lug
F22680C1AELX
F22680C1BELX

F44680C1AELX
F44680C1BELX

252 R1384 C 88 78 70 64 58
5 Way
Mount
Disconnect Plug
Solderless Lug
F22680C1CELX
F22680C1DELX
F44680C1CELX
F44680C1DELX
259 R1385
100 6.6 to 9.0 Volts
4 Steps
End Mount Disconnect Plug
Solderless Lug
F226100D1BELX F446100D1AELX
F446100D1BELX
275 R1384 D 66 61 57 52 49
5 Way
Mount
Disconnect Plug
Solderless Lug
F226100D1DELX F446100D1CELX
F446100D1DELX
282 R1385
125 7.8 to 10.0 Volts
4 Steps
End Mount Disconnect Plug
Solderless Lug
F226125F1BELX F446125F1AELX
F446125F1BELX
292 R1384 F 56 52 48 44 NA
5 Way
Mount
Disconnect Plug
Solderless Lug
F226125F1DELX F446125F1CELX
F446125F1DELX
299 R1385
150 9.4 to 11.7 Volts
4 Steps
End Mount Disconnect Plug
Solderless Lug
F226150DL1BELX F446150DL1AELX
F446150DL1BELX
310 R1384 DL 47 44 41 38 NA
5 Way
Mount
Disconnect Plug
Solderless Lug
F226150DL1DELX F446150DL1CELX
F446150DL1DELX
317 R1385

Standard Features:
• Class "F" insulation
• Totally enclosed tap switch
• Secondary end positively seales against contamination
• Blade type plug if applicable
• Interchangeable with other maufacturers
Optional Features:
• Voltages and frequencies other than shown available on request
• Thermostats
   
Bulletin F-1 Bulletin F-2 Bulletin F-2.1 Bulletin F-2.2 Bulletin F-3 Bulletin F-4 Bulletin F-4.1 Bulletin F-5