Machine Type Transformers » Bulletin M-2.1
General Description:
• Machine Type Transformer
• Stacked Core
• Frame Cross Section 10 3/4" X 13 3/8"
Ordering Instructions:
• Order by model number shown
• Add "X" to model number if transformer is to be fully potted
• Specify "primary conduit opening" or "primary cable clamp block" ("primary conduit opening" furnished standard)
• For a drawing, click on the appropriate link, and send an email request to sales@romanmfg.com

Stacked Core

KVA Rating 110C Rise Secondary Voltage Range Number of Taps Tap Switch Location RWMA Pad Size Model Number Weight Approx. Drawing No. Frame Letter Turns Ratio 440 Volt
220V/60 Hz 440V/60 Hz Tap
1
Tap
2
Tap
3
Tap
4
Tap
5
Tap
6
Tap
7
Tap
8
100 5.5 to 10.0
Volts
8 End Mount 1
2
3
M226100ML1BML
M226100ML1BNL
M226100ML1BOL
M446100ML1BML
M446100ML1BNL
M446100ML1BOL
420
423
427
R1471 ML 80:1 74:1 68:1 62:1 57:1 52:1 48:1 44:1
Side Mount 1
2
3
M226100ML1FML
M226100ML1FNL
M226100ML1FOL
M446100ML1FML
M446100ML1FNL
M446100ML1FOL
440
443
447
R1472
125 6.6 to 12.2
Volts
8 End Mount 1
2
3
M226125MA1BML
M226125MA1BNL
M226125MA1BOL
M446125MA1BML
M446125MA1BNL
M446125MA1BOL
490
493
501
R1471 MA 66:1 60:1 55:1 50:1 46:1 42:1 39:1 36:1
Side Mount 1
2
3
M226125MA1FML
M226125MA1FNL
M226125MA1FOL
M446125MA1FML
M446125MA1FNL
M446125MA1FOL
510
513
517
R1472

Standard Features:
• Class "F" insulation
• Solderless lug connections for primary wiring
• Secondary pad sizes and hole spacings to RWMA standard
• Secondary end positively sealed against contimination
Optional Features:
• Voltages and frequencies other than shown available on request
• Thermostats
• Special secondary pad sizes available on request
• Primary disconnect plug
   
Bulletin M-1 Bulletin M-2 Bulletin M-2.1 Bulletin M-3 Bulletin M-4