Machine Type Transformers » Bulletin M-4
General Description:
• Machine Type Transformer
• Stacked Core
• Frame Cross Sections:

- for V & VA frames 13 3/8" X 20 3/4"
- for U & UA frames 16 1/2" X 20 3/4"

Ordering Instructions:
• Order by model number shown
• Add "X" to model number if transformer is to be fully potted
• For a drawing, click on the appropriate link, and send an email request to sales@romanmfg.com

Stacked Core

KVA Rating 110C Rise Secondary Voltage Range Number of Taps Tap Switch Location RWMA Pad Size Model Number Weight Approx. Drawing No. Frame Letter Turns Ratio 440 Volt
220V/60 Hz Tap
1
Tap
2
Tap
3
Tap
4
Tap
5
Tap
6
Tap
7
Tap
8
250 7.6 to 13.8 Volts 8 End Mount 3 M446250V1BOL 975 R1286 V 58:1 53:1 49:1 45:1 41:1 38:1 35:1 32:1
300 8.6 to 15.7 Volts 8 End Mount 3 M446300VA1BOL 1085 R1286 VA 51:1 47:1 43:1 39:1 36:1 33:1 30:1 28:1
300 8.6 to 15.7 Volts 8 End Mount 4 M446300VA1BPL 1100 R1286 VA 51:1 47:1 43:1 39:1 36:1 33:1 30:1 28:1
400 8.8 to 16.9 Volts 8 End Mount 4 M446400U1BPL 1465 R1286 U 50:1 46:1 42:1 38:1 34:1 31:1 28:1 26:1
500 9.8 to 18.3 Volts 8 End Mount 4 M446500UA1BPL 1545 R1286 UA 45:1 41:1 37:1 34:1 31:1 28:1 26:1 24:1

Standard Features:
• Class "F" insulation
• Solderless lug connections for primary wiring
• Secondary pad sizes and hole spacings to RWMA standard
• Secondary end positively sealed against contimination
Optional Features:
• Voltages and frequencies other than shown available on request
• Thermostats
• Special secondary pad sizes available on request
• Primary disconnect plug
   
Bulletin M-1 Bulletin M-2 Bulletin M-2.1 Bulletin M-3 Bulletin M-4